Comparison of diagnostic methods for hemodynamic treatment in unborn and pre-term infants using the measurement of vena cava, lactate, and clinical criteria Original Research

Main Article Content

Geyson Deley Muñoz
Fabricio González Andrade

Abstract

Introduction: There is no single criterion available to assess the hemodynamic state of new-born infants and preterm infants and the different variables in the group of newborns, such as gestational age, birth weight, and periods of birth.


Methods: This is an epidemiological, cross-sectional, descriptive observational study with two patient cohorts. Newborn-to-term and preterm neonates assisted at the Neonatal Unit of the Pablo Arturo Suarez Hospital participated during the months between November 2019 to January 2020.


Results: Ultrasound measurement of the vena cava (FVC) flow is useful for the management treatment of hemodynamically unstable neonatal patients. The sample was made up of 110 newborns treated in the Pablo Arturo Suarez Hospital's neonatology service from November 2019 to January 2020. Quito, Pichincha, Ecuador. The variables low birth weight and moder-ate prematurity have a statistically significant value for inotropic use. The other variables do not present statistically significant values. Heart rate, urinary output, mean blood pressure, lactic acid, capillary filling, upper vena cava flow, and lower vena cava flow had statistically significant values. FVCI and FVCS comparisons with heart rate, urinary output, mean blood pressure, lactic acid, and capillary filling had statistically significant values, except for capil-lary filling> 3 sec in FCVI. Multivariate analysis of categorical main components (CATPCA) was used to characterize the hemodynamic state and inotropic state, which were significant in the bivariate analysis. Dimension, one of the two-dimensional graphs, discriminates the use or not of inotropics and the categories of hemodynamic parameters TAM <35 mmHg, lactic acid, capillary filling, FVCI, and FVCS. Dimension II discriminates between the categories of urinary expenditure and HR.


Conclusion: In term and preterm infants with low weight and adequate birth weight with hemodynamic instability in general, who were evaluated with ultrasonography to measure the flow of the vena cava, the agreement between the clinical criteria and the ultrasound assessment of the flow was 0.4 cm/sec in both methods. This situation means that the measurement of venous cava flows by echo sonography is useful for assessing neonatal patients' hemodynamic status.

Downloads

Download data is not yet available.

Article Details

How to Cite
Deley Muñoz, G. ., & González Andrade, F. (2021). Comparison of diagnostic methods for hemodynamic treatment in unborn and pre-term infants using the measurement of vena cava, lactate, and clinical criteria: Original Research. Revista Ecuatoriana De Pediatría, 22(3), 1-9. https://doi.org/10.52011/81
Section
Original Articles